---
name: verbex-lab-tools
description: Exact wet-lab calculations and lab paperwork from Verbex. Use when a scientist asks how much to weigh for a molarity, how much stock to dilute (C1V1), how to set up a serial dilution, a PCR or qPCR master mix, an LNP formulation or a 6- to 384-well plate layout; needs ELISA standard-curve fitting or BCA/Bradford protein concentrations through HTTP; needs a lab document template (SOP, protocol, lab notebook entry, freezer or chemical inventory, deviation log, risk assessment); wants reagent label text as a materials table; or asks how to write SOPs, keep lab notebooks, track inventory or meet data-integrity rules.
---

# Verbex Lab Tools

Exact answers for wet-lab bench work: the numbers to weigh and pipette, plate layouts, and lab documentation. From Verbex (https://www.verbalexperiment.com). No sign-in; inputs are used only to compute the answer and are not stored.

These free tools are separate from the paid iPhone/iPad notebook (https://www.verbalexperiment.com/app). They cannot read, update or synchronize the scientist's local app records. Browser label OCR accepts images; the label HTTP/MCP tool accepts already-extracted text.

## Choose by outcome

- Weigh a solute or dilute a stock: molarity-calculator / MCP solution_prep.
- Plan dilution tubes: serial-dilution-calculator / MCP serial_dilution.
- Prepare PCR/qPCR mixes: pcr-master-mix-calculator / MCP pcr_master_mix.
- Calculate lipid formulation: lnp-formulation-calculator / MCP lnp_formulation.
- Assign wells and replicates: 96-well-plate-map-builder / MCP plate_map.
- Draft a notebook or protocol scaffold: eln-template-builder or lab-protocol-template-builder / MCP eln_template or protocol_template.
- Structure reagent label text: reagent-label-scanner / MCP parse_reagent_label.
- Fit ELISA standards or calculate BCA/Bradford concentrations: standard-curve or protein-assay, HTTP/browser beta only; not production MCP.
- Turn a cell count into viable cells/mL and seeding volumes: hemocytometer-calculator, HTTP/browser only; not production MCP.
- Fetch schemas and example requests: https://www.verbalexperiment.com/tools/manifest.json . HTTP contract: https://www.verbalexperiment.com/openapi.json .

## Use it with no install

POST JSON to a calculator and show the user the `notebookEntry` from the response (Markdown: the answer, the formula and a check line). The response also has `result`, `validationErrors`, `warnings` and `safetyNotes`.

```bash
curl --fail-with-body -sS https://www.verbalexperiment.com/api/tools/molarity-calculator \
  -H 'Content-Type: application/json' \
  -d '{"mode":"solid","solutionName":"NaCl","molecularWeight":58.44,"targetConcentration":233,"targetConcentrationUnit":"mM","finalVolume":450,"finalVolumeUnit":"mL"}'
```

Units are written as in the examples (uL for µL, uM for µM). If a required value is missing, ask the scientist rather than guessing it; the response's validationErrors say what is missing.

## Handle the response

- 200 with ok true: use notebookEntry and the structured result. Preserve warnings, safetyNotes, units and precision; a successful calculation is not scientific or regulatory validation.
- 422: read validationErrors and ask for missing or invalid inputs. Do not present a failed calculation as a result.
- 400: fix malformed JSON. 413: reduce the request to the documented limits without silently dropping scientific readings.
- If rate-limited, respect Retry-After when supplied. On a server/network failure, report the failure; never invent a fallback numerical answer.
- Examples are synthetic demonstrations, not the scientist's measurements. Ask for their actual inputs before preparing a result for their experiment.

## Calculators

### Solution prep (molarity and C1V1)

Use when someone asks how much solid to weigh for a molar solution (how many grams for X mM in Y mL, making up a buffer or salt solution), or how much stock to dilute to a target concentration (C1V1). mode "solid": mass of solid to weigh from molecular weight, target concentration and final volume. mode "stock": C1V1 = C2V2 dilution from a stock, solving for stockVolume, stockConcentration, targetConcentration or finalVolume. Returns the primary result, a step summary, warnings and safety notes.

- Production MCP: `solution_prep`
- POST https://www.verbalexperiment.com/api/tools/molarity-calculator
- Input schema: https://www.verbalexperiment.com/schemas/tools/molarity-calculator.input.schema.json
- Example body: `{"mode":"stock","solutionName":"100 mM Tris solution","solveFor":"stockVolume","stockConcentration":1,"stockConcentrationUnit":"M","targetConcentration":100,"targetConcentrationUnit":"mM","finalVolume":100,"finalVolumeUnit":"mL","stockVolumeUnit":"mL","solvent":"water or buffer"}`
- Output schema: https://www.verbalexperiment.com/schemas/tools/molarity-calculator.output.schema.json
- Example response: https://www.verbalexperiment.com/examples/tools/molarity-calculator.response.json

### Serial dilution planner

Use for any serial dilution (standard curves, titrations, dose series). Plans transfer and diluent volume per tube and the resulting concentration at each step, from a stock concentration, a constant dilution factor, the number of tubes and the final volume per tube.

- Production MCP: `serial_dilution`
- POST https://www.verbalexperiment.com/api/tools/serial-dilution-calculator
- Input schema: https://www.verbalexperiment.com/schemas/tools/serial-dilution-calculator.input.schema.json
- Example body: `{"seriesName":"10-fold dilution series","stockConcentration":1200,"concentrationUnit":"x","dilutionFactor":10,"steps":3,"finalVolume":100,"volumeUnit":"uL"}`
- Output schema: https://www.verbalexperiment.com/schemas/tools/serial-dilution-calculator.output.schema.json
- Example response: https://www.verbalexperiment.com/examples/tools/serial-dilution-calculator.response.json

### PCR / qPCR master mix

Use when someone sets up a PCR or qPCR reaction mix for several wells. Calculates volume of each component per reaction and for the whole mix with excess, with water filling the remaining volume. Give each component a stock and final concentration (molar, ng/µL, x buffer, %), an amount per reaction (e.g. 1.25 U polymerase from 5 U/µL, 10 ng template from ng/µL), or a fixed volume. Template can be added per well separately. Do not list water; it is calculated.

- Production MCP: `pcr_master_mix`
- POST https://www.verbalexperiment.com/api/tools/pcr-master-mix-calculator
- Input schema: https://www.verbalexperiment.com/schemas/tools/pcr-master-mix-calculator.input.schema.json
- Example body: `{"reactionName":"IL-6 qPCR, plate 2","reactions":46,"reactionVolume":20,"reactionVolumeUnit":"uL","excessPercent":10,"templateVolume":2,"components":[{"name":"2x SYBR Green master mix","stockConcentration":2,"stockUnit":"x","finalConcentration":1,"finalUnit":"x"},{"name":"Forward primer","stockConcentration":10,"stockUnit":"uM","finalConcentration":400,"finalUnit":"nM"},{"name":"Reverse primer","stockConcentration":10,"stockUnit":"uM","finalConcentration":400,"finalUnit":"nM"}]}`
- Output schema: https://www.verbalexperiment.com/schemas/tools/pcr-master-mix-calculator.output.schema.json
- Example response: https://www.verbalexperiment.com/examples/tools/pcr-master-mix-calculator.response.json

### LNP formulation (lipid nanoparticles)

Plan a lipid nanoparticle (LNP) formulation for RNA: from RNA mass, N/P ratio and lipid mol% (e.g. ionizable lipid/DSPC/cholesterol/PEG-lipid 50/10/38.5/1.5), calculate moles, mass and stock volume of every lipid, the ethanol and aqueous phase volumes at the chosen mixing ratio (default 3:1), and final RNA concentration, ethanol fraction and lipid:RNA ratio. Molecular weights must come from the user or certificates of analysis.

- Production MCP: `lnp_formulation`
- POST https://www.verbalexperiment.com/api/tools/lnp-formulation-calculator
- Input schema: https://www.verbalexperiment.com/schemas/tools/lnp-formulation-calculator.input.schema.json
- Example body: `{"formulationName":"SM-102 LNP, luciferase mRNA","rnaMass":100,"rnaMassUnit":"ug","rnaStockConcentration":1,"rnaStockUnit":"mg/mL","npRatio":6,"aqueousToEthanolRatio":3,"aqueousVolume":750,"aqueousVolumeUnit":"uL","lipids":[{"name":"SM-102","molPercent":50,"molecularWeight":710.17,"stockConcentration":25,"stockUnit":"mg/mL","ionizable":true},{"name":"DSPC","molPercent":10,"molecularWeight":790.15,"stockConcentration":10,"stockUnit":"mg/mL"},{"name":"Cholesterol","molPercent":38.5,"molecularWeight":386.65,"stockConcentration":10,"stockUnit":"mg/mL"},{"name":"DMG-PEG2000","molPercent":1.5,"molecularWeight":2509.2,"stockConcentration":10,"stockUnit":"mg/mL"}]}`
- Output schema: https://www.verbalexperiment.com/schemas/tools/lnp-formulation-calculator.output.schema.json
- Example response: https://www.verbalexperiment.com/examples/tools/lnp-formulation-calculator.response.json

### Plate map (6- to 384-well)

Use when someone lays out a multiwell plate (ELISA, qPCR, cell or compound assays). Lays out a 6, 12, 24, 48, 96 or 384-well plate: standards, samples, controls and blanks with replicates, filled by row or column, optionally leaving edge wells empty and keeping replicate sets together. Returns a grid with a key and a well-by-well list.

- Production MCP: `plate_map`
- POST https://www.verbalexperiment.com/api/tools/96-well-plate-map-builder
- Input schema: https://www.verbalexperiment.com/schemas/tools/96-well-plate-map-builder.input.schema.json
- Example body: `{"plateName":"ELISA IL-6 plate 1","format":96,"standards":{"name":"Std","points":8,"replicates":2},"samples":["Patient 01","Patient 02","Patient 03","Patient 04","Patient 05","Patient 06","Patient 07","Patient 08","Patient 09","Patient 10"],"replicates":3,"controls":["Positive control"],"controlReplicates":2,"blanks":2,"fillDirection":"column"}`
- Output schema: https://www.verbalexperiment.com/schemas/tools/96-well-plate-map-builder.output.schema.json
- Example response: https://www.verbalexperiment.com/examples/tools/96-well-plate-map-builder.response.json

### Lab protocol template

Build a structured lab protocol (purpose, materials, procedure, critical steps, acceptance criteria and more) for a protocol title, using a preset or custom sections. Returns Markdown and HTML ready to fill in or print.

- Production MCP: `protocol_template`
- POST https://www.verbalexperiment.com/api/tools/lab-protocol-template-builder
- Input schema: https://www.verbalexperiment.com/schemas/tools/lab-protocol-template-builder.input.schema.json
- Example body: `{"protocolTitle":"ELISA protocol scaffold","presetId":"elisa","includeExecutionNotes":true,"includeVersionHistory":true,"sectionItems":[{"id":"elisaPurpose","source":"library"},{"id":"elisaPlateLayout","source":"library"},{"id":"elisaStandardsControls","source":"library"},{"id":"elisaReagents","source":"library"},{"id":"elisaProcedure","source":"library"},{"id":"elisaAcceptanceCriteria","source":"library"},{"id":"versionHistory","source":"library"}]}`
- Output schema: https://www.verbalexperiment.com/schemas/tools/lab-protocol-template-builder.output.schema.json
- Example response: https://www.verbalexperiment.com/examples/tools/lab-protocol-template-builder.response.json

### Electronic lab notebook entry template

Build an electronic lab notebook (ELN) entry template for an experiment: objective, materials, procedure, observations and conclusion sections from a preset or custom list, optionally with timestamp fields and voice-capture prompts. Returns Markdown and HTML.

- Production MCP: `eln_template`
- POST https://www.verbalexperiment.com/api/tools/eln-template-builder
- Input schema: https://www.verbalexperiment.com/schemas/tools/eln-template-builder.input.schema.json
- Example body: `{"experimentTitle":"Cell culture passage record","presetId":"cellCulture","includeTimestamps":true,"includeVoicePrompts":true,"sectionItems":[{"id":"objective","source":"library"},{"id":"materials","source":"library"},{"id":"procedure","source":"library"},{"id":"observations","source":"library"},{"id":"deviations","source":"library"},{"id":"custom-cell-health","source":"custom","title":"Cell Health Notes"},{"id":"review","source":"library"}]}`
- Output schema: https://www.verbalexperiment.com/schemas/tools/eln-template-builder.output.schema.json
- Example response: https://www.verbalexperiment.com/examples/tools/eln-template-builder.response.json

### Reagent label parser

Turn text read from a reagent bottle or kit label (OCR or typed) into structured fields such as product name, catalog number, lot, expiry, concentration and storage. Parses the provided text only; send the label text, not an image.

- Production MCP: `parse_reagent_label`
- POST https://www.verbalexperiment.com/api/tools/reagent-label-scanner
- Input schema: https://www.verbalexperiment.com/schemas/tools/reagent-label-scanner.input.schema.json
- Example body: `{"ocrText":"Cellartis\nPower Primary HEP Medium\nY20020\nLot AOX0016S\nExp OCT. 2025\nStore at -20C\n250 mL","sourceImageName":"cellartis-hep-medium-label.jpg","ocrConfidence":92}`
- Output schema: https://www.verbalexperiment.com/schemas/tools/reagent-label-scanner.output.schema.json
- Example response: https://www.verbalexperiment.com/examples/tools/reagent-label-scanner.response.json

### Standard curve (ELISA, beta)

Use when someone has ELISA or other immunoassay plate readings and wants a standard curve, sample concentrations, or to know whether their standards fit. Fits a 4PL (5PL only when the standards support it), back-calculates every standard, sets the working range (LLOQ to ULOQ) and reports samples only inside it, with dilution factors applied; never extrapolates. Send concentrationUnit, standards as {concentration, responses: [replicate readings]}, optional blanks and samples [{name, responses, dilutionFactor}]. Default limits follow ICH M10: recovery within ±20% (±25% at LLOQ and ULOQ), replicate CV ≤ 20%, at least 75% and 6 levels passing. They are defaults: pass limits to tighten or relax them, and every result states the limits it used. Exclude a standard only with a reason the scientist gives. Beta, checked against published datasets (agreement within about 1%): report the flags and call results checked, not validated.

- Availability: beta browser/HTTP API; not available in production MCP.
- POST https://www.verbalexperiment.com/api/tools/standard-curve
- Input schema: https://www.verbalexperiment.com/schemas/tools/standard-curve.input.schema.json
- Example body: `{"assayName":"IL-6 ELISA plate 1","concentrationUnit":"pg/mL","standards":[{"concentration":4.69,"responses":[0.118,0.124]},{"concentration":9.38,"responses":[0.171,0.165]},{"concentration":18.75,"responses":[0.27,0.281]},{"concentration":37.5,"responses":[0.482,0.468]},{"concentration":75,"responses":[0.861,0.889]},{"concentration":150,"responses":[1.512,1.478]},{"concentration":300,"responses":[2.341,2.398]},{"concentration":600,"responses":[2.902,2.951]}],"blanks":[0.052,0.049],"samples":[{"name":"Patient 01","responses":[0.655,0.671],"dilutionFactor":2},{"name":"Patient 02","responses":[3.05,3.08],"dilutionFactor":2},{"name":"Patient 02","responses":[1.2,1.24],"dilutionFactor":20},{"name":"Patient 03","responses":[0.06,0.061]}]}`
- Output schema: https://www.verbalexperiment.com/schemas/tools/standard-curve.output.schema.json
- Example response: https://www.verbalexperiment.com/examples/tools/standard-curve.response.json

### Protein assay (BCA, Bradford, beta)

Use when someone has BCA or Bradford (or other colorimetric) protein assay readings and wants sample protein concentrations, or how much lysate to load for a western blot. Subtracts the blank, fits a quadratic standard curve (linear or 4PL on request), back-calculates every standard, and reports sample concentrations only within the working range, with dilution factors applied. Optional loading: give a protein mass per lane (e.g. 20 µg) and the lane volume to get the µL of sample and buffer for each. Send concentrationUnit (e.g. ug/mL), standards as {concentration, responses}, blanks, samples [{name, responses, dilutionFactor}]. Default limits are Verbex protein-assay defaults (recovery ±15%, ±25% at the end standards, replicate CV ≤ 15%); no regulatory guideline sets these, and every result states the limits used. Concentrations are relative to the standard protein (usually BSA). Beta: report the flags and call results checked, not validated.

- Availability: beta browser/HTTP API; not available in production MCP.
- POST https://www.verbalexperiment.com/api/tools/protein-assay
- Input schema: https://www.verbalexperiment.com/schemas/tools/protein-assay.input.schema.json
- Example body: `{"assayName":"BCA, cell lysates","concentrationUnit":"ug/mL","standards":[{"concentration":25,"responses":[0.08,0.083]},{"concentration":125,"responses":[0.198,0.192]},{"concentration":250,"responses":[0.341,0.35]},{"concentration":500,"responses":[0.611,0.602]},{"concentration":750,"responses":[0.85,0.862]},{"concentration":1000,"responses":[1.071,1.083]},{"concentration":1500,"responses":[1.45,1.468]},{"concentration":2000,"responses":[1.762,1.79]}],"blanks":[0.052,0.05],"samples":[{"name":"Lysate A","responses":[0.712,0.705],"dilutionFactor":5},{"name":"Lysate B","responses":[0.402,0.41],"dilutionFactor":5},{"name":"Lysate C","responses":[1.95,1.97],"dilutionFactor":1}],"loading":{"mass":20,"massUnit":"ug","finalVolume":20}}`
- Output schema: https://www.verbalexperiment.com/schemas/tools/protein-assay.output.schema.json
- Example response: https://www.verbalexperiment.com/examples/tools/protein-assay.response.json

### Cell count and seeding (hemocytometer)

Use when someone has counted cells (hemocytometer squares, or cells/mL from an automated counter) and needs the concentration, the viability, or how much cell suspension and medium to put in each well, dish or flask. Count: send liveCounts (cells per square, e.g. [60, 66, 69, 75]), optional deadCounts for viability, and the volumes mixed with trypan blue (sampleVolume, dyeVolume) so the dilution factor is worked out; or send viableCellsPerMl from a counter. Seeding plan (optional): target with targetUnit (cells/vessel, cells/cm2 or cells/mL; always say which), vessel (6-well to 384-well plates, 35 to 150 mm dishes, T-25 to T-225 flasks) or growthArea in cm², vesselCount and workingVolume; add suspensionVolume to check there are enough cells. Returns viable cells/mL, every step of the working, the suspension and medium per vessel and for the whole batch with extra, and flags for counts worth repeating (too few cells, outside the countable range, uneven squares). It does not choose a seeding density for a cell line.

- Availability: beta browser/HTTP API; not available in production MCP.
- POST https://www.verbalexperiment.com/api/tools/hemocytometer-calculator
- Input schema: https://www.verbalexperiment.com/schemas/tools/hemocytometer-calculator.input.schema.json
- Example body: `{"cultureName":"HEK293, passage 12","chamber":"neubauer-large","liveCounts":[60,66,69,75],"deadCounts":[4,3,5,4],"sampleVolume":10,"dyeVolume":10,"dilutionVolumeUnit":"uL","suspensionVolume":10,"suspensionVolumeUnit":"mL","target":300000,"targetUnit":"cells/vessel","vessel":"6-well","vesselCount":6,"workingVolume":2,"workingVolumeUnit":"mL","extraPercent":10}`
- Output schema: https://www.verbalexperiment.com/schemas/tools/hemocytometer-calculator.output.schema.json
- Example response: https://www.verbalexperiment.com/examples/tools/hemocytometer-calculator.response.json

## Templates and guides

- The 16 lab documentation templates: https://www.verbalexperiment.com/templates/index.md. Each /templates/<id>.md has the template text, a worked example where there is one, and a link to the editable Word or Excel file.
- Guides on SOPs, lab notebooks, inventory, data integrity and bench math, by topic: https://www.verbalexperiment.com/llms.txt. Any guide as Markdown: https://www.verbalexperiment.com/blog/<slug>.md
- Cite the url of any template or guide you use.

## Or connect over MCP

https://www.verbalexperiment.com/mcp (Streamable HTTP, no sign-in). Tools: search and fetch (guides and templates) plus calculators marked Production MCP above. Standard-curve and protein-assay analysis are available through the browser/HTTP API only. Setup for Claude, Cursor and others: https://www.verbalexperiment.com/agents

## How to answer

- Lead with the number to use, exactly as returned, with units and the same significant figures.
- Show the check line, warnings and safety notes. Call the result "checked", not "validated".
- Results are calculation and documentation aids; the scientist checks them against their own lab's requirements.
